  1. RV Pedestal Bonding | Information by Electrical Professionals for ...

    May 10, 2024 · Does each pedestal have an individual run to the transformer or did they daisy chain conductors between pedestals? Individual run to each pedestal would comply with 230.2 and 230.40 …

  2. pedestal combination meter and main | Information by Electrical ...

    Feb 3, 2005 · Re: pedestal combination meter and main George, the meter pedestal has a main disconnecting means, it is a structure, and everything downstream is being fed from a feeder from …

  3. Grounding Electrode for RV Pedestal??? | Information by Electrical ...

    Feb 16, 2023 · 1st ISSUE Is a grounding electrode required for an RV pedestal that has a 50 amp breaker and receptacle with a 20 amp receptacle and breaker? If my understanding is correct it is not …

  4. Pedestal service grounding | Information by Electrical Professionals ...

    Nov 1, 2005 · Re: Pedestal service grounding Reading this section it sounds like I can leave the tri-plex and use the bare wire as the neutral. At the utility pole I will make sure the ground and N are …

  5. Grounding an RV Power Outlet Pedestal | Information by Electrical ...

    Oct 19, 2005 · Re: Grounding an RV Power Outlet Pedestal Yes, this must be connected to an equipment bonding conductor back to the power source. To rely solely on a ground rod without a …

  6. From service pedestal to house...3 or 4 wire? | Information by ...

    Oct 8, 2013 · The service pedestal qualifies as a structure and any wiring from that point of main disocnnect becomes a feeder. To be real concise, we dont know that the disconnecting means for …

  7. RV park pedestals | Information by Electrical Professionals for ...

    Mar 11, 2007 · I believe that 551.7 specifies an equipment grounding conductor, and doesn't allow you to use the neutral to ground the pedestals. Idon't find a requirement for a ground rod at the …

  8. rv pedestal in mobile home park | Information by Electrical ...

    Apr 5, 2024 · Customer wants to hook up a rv pedestal in mobile home park. poco is about 50ft away i wanted to put a 100amp feed through panel under the meter at the poco pole. Run 1/o, 1/o, 1/o, 1/o, …

  9. 2020 NEC 551.71(F) : GFCI at new RV Pedestal, inspectors want 50A and ...

    Nov 1, 2024 · Now we have an earth pedestal combo with a meter (20A, 30A, 50A built in) we want to put in with a direct bored conduit from a transformer or H.H. The inspector is saying we need to swap …

  10. Remote pedestal feed to the house | Information by Electrical ...

    Oct 7, 2018 · I have a remote pedestal where my meter base is located. Also on the pedestal is my 200 amp breaker for my house. The feed then runs to a disconnect on the side of the house, then feeds …